Power Transmission and Distribution Experiment System
Model Number: GOTT-TML-1
Brand: GOTT
C/O: Malaysia
DESCRIPTION
Using the Power Transmission Line trainer set it will be possible to assemble an absolute power transmission system. From a transformer with tapping switch to the power circuit breaker and 415V power transmission line model, including line termination with surge impedance. Various experiments can be are carried out on this power transmission system, no load operation with natural load, asymmetrical and asymmetrical short circuit, parallel and series compensation of the transmission line as well as neutral-point connection.
PRODUCT MODULE
THREE PHASE TRANSFORMER TL415KV
CODE 157-889
Transformer for feeding the transmission line model 415V. Scale factor 1:1000 for secondary current and voltage. Nominal Power: 800VA Primary: 3 x 400 V winding with tapping at 230V, can be switched to star or delta connection Delta stabilizing winding can be connected. Secondary: 3 x 380 V winding with tap-pings at +5%, -5%, -10%, -15% in star connection, various star Point connections possible
TRANSMISSION LINE MODEL 415V
CODE 157-891
Measuring steady state operating conditions. Quad bundle 4 x 240/40, with surge impedance 240 and natural load 600 MW, length 360 km. Resistance: 13 Ohm, 8 Ohm, 5 Ohm Inductance: 290 mH, 174 mH, 116 mH Open Capacity: 5 μ F, 3 μ F, 2 μ F
INVERTER UNIT
CODE 157-895
3Ø asynchronous motor speed control by PWM technique. The Torque and Speed are able to be constant via the unit to easy control in testing operation during loads change. Input Voltage: 380V, 50Hz Output Voltage: 0-380V Out Frequency: 1-300Hz Max Power: 1.5 kW
THREE PHASE POWER SUPPLY
CODE 157-896
Fixed and variable AC supplies. Provided with start stop/stop push bottom EMO. Three Phase AC Adjustable Output : 3×0-380V: 6A Three Phase AC Fixed Output: 240/415V: 10A Power Requirement: 240/415V, 50Hz
RESISTIVE LOAD
CODE 157-897
Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase. Max Power: 1200 watt Voltage: 415/240Volt (Star/Delta)
INDUCTIVE LOAD
CODE 157-898
Compose of three inductances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase. Max Power: 900VAR Voltage: 415/240Volt (Star/Delta)
POWER CIRCUIT BREAKER MODULE
CODE 157-892
3-phase ON-OFF switch with auxiliary contact (NC) for transmission line model 380 kV. Can be controlled manually using ON/OFF pushbutton or externally via switching contact, 4-mm sockets.
EARTH FAULT COMPENSATION
CODE 157-893
Inductance with 20 tappings for earth fault compensation in the 415 kV transmission line model (Petersen coil). Inductance L: 0.005….2 H Rated voltage: 240V, 50 Hz Rated current: 0.5 A
CAPACITIVE LOAD
CODE 157-899
Compose of three capacitances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase. Max Power: 900VAR Voltage : 415/240Volt (Star/Delta)
TRANSMISSION LINE CAPACITOR TL 415 KV
CODE 157-891
3-phase in star connection, 2.5 μF each, corresponds to 50 % of the operating capacitance of transmission line model 415 Kv.
EXCITATION VOLTAGE CONTROLLER
CODE 157-894
DC power supply unit suitable to supply 0-240VDC, 0-2A adjustable for excitation voltage in synchronous as generator operation.
THREE PHASE CONTACTOR WITH OVERLOAD RELAY
CODE 157-900
Voltage: 415VAC Range: 0-4A Coil: 240VAC
ELECTRICAL METER
CODE 157-901
Measurement: V, KV, Hz, A, KA, S, KW, KVAR, KVA, KWH, KVRH
KILOWATT HOUR METER
CODE 456-014
Speed: 1200 turn/ 1kW/Hour Accuracy : Class 1.5
SIMULATE SWITCH BOARD
CODE 191-113
Rated voltage: 240VAC Push Button X 3 units
AC VOLMETER & AC AMMETER
CODE 588-027
Measurement Mode: AC Voltage Ranges : 5V, 50V, 250V, 1000V Current Ranges : 1A, 5A, 25A
THREE PHASE INDUCTION MOTOR
CODE 159-004
Power: 170W Voltage: 415VAC Current: 0.45A Speed: 1500rpm Connection: Δ & Υ
SINGLE PHASE SYNCHRONIZATION GENERTOR
CODE 159-006
Power: 250W Voltage: 240VAC Current: 2A Speed: 1400rpm
THREE PHASE SYNCHRONOUS GENERATOR
CODE 159-005
Power: 170W Voltage: 415VAC Current: 0.43A Excitation Voltage: 12VDC Excitation Current: 14A Speed: 1500rpm Connection: Y
PULLEY AND RUBBER COUPLING
CODE 431-000
U-LINK
CODE 159-019
A unit which is wed to link the unit together
SAFETY CONNECTING LEAD
CODE 237-001
4mm connecting leads
VERTICAL FRAME
CODE 297-000
High level: DIN standard A4 with two shelves Material: Aluminium Side Frame: T shape Size: 3-Layer 1450mm Length
EXPERIMENT MANUAL
CODE 157-902
EXPERIMENT TOPICS :
- Symmetrical load and unsymmetrical load connection
- Voltage and frequency control by inverter unit
- Characteristic of transformer feeder
- RL circuits in transmission line
- RC circuits in transmission line
- RLC circuits in transmission line
- Earth fault compensation and its characteristic
- Excitation voltage controller with motor generator
- Characteristic of generating voltage
- Measuring power in each line
Manuals:
- All manuals are written in English
- Model Answer
- Teaching Manuals
General Terms:
- Accessories will be provided where applicable
- Manuals & Training will be provided where applicable.
- Designs & Specifications are subject to change without notice.
- We reserve the right to discontinue the manufacturing of any product