Microwave Passive Circuit Design Trainer
Model: GOTT-MSP-170
Brand: GOTT
C/O: Malaysia
DESCRIPTION
- Design and implementation of switches and attenuators.
- Design and implementation of Wilkinson power dividers, branch line couplers and Lange couplers.
- Design and implementation of ring coupler, directional coupler and baluns.
- Design and implementation of low -pass filter, band-stop filter and band-pass filter.
- Design and implementation of PBG Filter and DGS type filter.
FEATURES
- Training for wireless communication technicians and engineers.
- To understand the applications and measurements of communication instruments and products.
- Design and implementation ability training for microwave module circuit.
- To understand the applications of micro-strip line in microwave circuits design.
- To shorten the gap between academic and industrial circles.
PRODUCT MODULES DESIGN AND IMPLEMENTATION OF SWITCH & ATTENUATOR
CODE 170-001
Design and Implementation of Switch
- Experiment 1: Single Pole SPDT Switching (Operation Frequency: 2400 MHz; Return Loss: > 10 dB; Insertion Loss: < 3 dB; Isolation: > 10 dB)
- Experiment 2: Double Pole SPDT Switching (Operation Frequency: 2400 MHz; Return Loss: > 10 dB; Insertion Loss: < 3 dB; Isolation: > 10 Db)
- Experiment 3: Doubly Poles High Isolation SPDT Switching (Operation Frequency: 2400 MHz; Return Loss: > 10 d B; Insertion Loss: < 3 dB; Isolation: > 20 dB)
Design and Implementation of Attenuator
- Experiment 1: π-type Attenuator (Operation Frequency: 2400 MHz; Return Loss: > 15 dB; Attenuation: > 20 ± 3 dB)
- Experiment 2: T-type Attenuator (Operation Frequency: 2400 MHz; Return Loss: > 15 dB; Attenuation: > 20 ± 3dB)
- Experiment 3: Voltage-controlled -type Attenuator (Operation Frequency: 2400 MHz; Return Loss: > 10 dB; Attenuation: > 30 ~ 10 ± 3 dB)
DESIGN AND IMPLEMENTATION OF WIKINSON POWER DIVIDER
CODE 170-002
Design and Implementation of Wilkinson Power Divider
- Experiment 1: Single Stage Wilkinson Power Divider (Operation Frequency: 2400 MHz; Return Loss: > 25 ± 5 dB; Coupling: < – 3 ± 0.5 dB; Isolation: > 25 ± 5 dB; Phase difference: 0 ± 5 deg.)
- Experiment 2: SIR Wilkinson Power Divider (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 0.5 dB; Isolation: > 15 ± 5 dB; Phase difference: 0 ± 5 deg.)
- Experiment 3: Two Stages Wilkinson Power Divider (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 25 ± 5 dB; Phase difference: 0 ± 5 deg.)
- Experiment 4: Unequal Power Wilkinson Power Divider (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB; Coupling: < -2 ± 0.5 dB; Isolation: >20 ± 5 dB; Phase difference: 0 ± 5 deg.)
DESIGN AND IMPLEMENTATION OF BRANCH LINE COUPLER
CODE 170-003
Design and Implementation of Branch line Coupler
- Experiment 1: One Single Stage Branch Line Coupler (Operation Frequency: 2400 MHz; Return Loss: > 30 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 25 ± 5 dB; Phase difference: -270 ± 10 deg.)
- Experiment 2: Size Reduced Branch Line Coupler (Operation Frequency: 2400 MHz; Return Loss: > 30 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 25 ± 5 dB; Phase difference: 75 ± 10 deg.
- Experiment 3: Branch Line Coupler with Second Harmonic Suppression (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 35 ± 5 dB; Phase difference: -270 ± 10 deg.)
- Experiment 4: Two Stage s Branch Line Coupler (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 25 ± 5 dB; Phase difference: 90 ± 10 deg.)
DESIGN AND IMPLEMENTATION OF LANGE COUPLER
CODE 170-004
Design and Implementation of Lange Coupler
- Experiment 1: Unfolded Lange Coupler (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB Coupling: < -6 ± 0.5 dB; Isolation: > 30 ± 5 dB; Phase difference: -90 ± 10 deg.)
- Experiment 2: Single Stage Lange Coupler (Operation Frequency: 2400 MHz; Return Loss: > 35 ± 5 dB; Coupling: < -6 ± 0.5 dB; Isolation: > 30 ± 5 dB; Phase difference: -90 ± 10 deg.)
- Experiment 3: Two Stages Lange Coupler (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 25 ± 5 dB; Phase difference: -90 ± 10 deg.)
- Experiment 4: Triple Coopered Lines Lange Coupler (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 30 ± 5 dB; Phase difference: -90 ± 10 deg.) D
ESIGN AND IMPLEMENTATION OF RING COUPLER
CODE 170-005
Design and Implementation of Ring Coupler
- Experiment 1: 180 deg. Ring Coupler (Operation Frequency: 2400 MHz; Return Loss: > 25 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 35 ± 5 dB; Phase difference: 0 ± 10 deg. / -180 ± 10 deg.)
- Experiment 2: Wideband Ring Coupler (Operation Frequency: 2400 MHz; Return Loss: > 25 ± 5 dB; Coupling: < -3 ± 0.5 dB; Isolation: > 20 ± 5 dB; Phase difference: -10 ± 10 deg. / -190 ± 10 deg.)
- Experiment 3: Size Reduced Ring Coupler (Operation Frequency: 2400 MHz; Return Loss: > 25 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 25 ± 5 dB; Phase difference: 0 ± 10 deg. / -180 ± 10 deg.)
- Experiment 4: Miniaturized Ring Coupler (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 20 ± 5 dB; Phase difference: -3 ± 10 deg. / -175 ± 10 deg.)
DESIGN AND IMPLEMENTATION OF DIRECTIONAL COUPLER & BALUN
CODE 170-006
Design and Implementation of Directional Coupler
- Experiment 1: Single Stage Directional Coupler (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB; Coupling: < – 10 ± 1 dB; Isolation: > 20 ± 5 dB; Phase difference: -90 ± 10 deg.)
- Experiment 2: Multi-stages Directional Coupler (Operation Frequency: 2400 MHz; Return Loss: > 20 ± 5 dB; Coupling: < – 6 ± 1 dB; Isolation: > 20 ± 5 dB; Phase difference: 90 ± 10 deg.) Design and Implementation of Balun
- Experiment 1: Novel Parallel Line Lange Balun (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 7 ± 5 dB; Phase difference: -180 ± 10 deg.)
- Experiment 2: Multi-stage Coupled Line Balun (Operation Frequency: 2400 MHz; Return Loss: > 15 ± 5 dB; Coupling: < -3 ± 1 dB; Isolation: > 7 ± 5 dB; Phase difference: -180 ± 10 deg.)
DESIGN AND IMPLEMENTATION OF LOW-PASS FILTER
CODE 170-007
Design and Implementation of Low-pass Filter
- Experiment 1: Stepped Impedance Low-pass Filter (f-3dB: 2.4 ± 0.1 GHz; Pass-band Width: > 2.4 ± GHz; -20 dB Band- stop: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB;Insertion Loss: < 0 dB ± 1dB)
- Experiment 2: Compact Stepped Impedance Low-pass Filter (f-3dB: 2.4 ± 0.1 GHz; Pass-band Width: > 2.4 ± 0.1 GHz; -20 dB Stop-band: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 3: Branch Line Type Low-pass Filter (f-3dB: 2.4 ± 0.1 GHz; Pass-band Width: > 2.4 ± GHz; -20 dB Stop-band > 3 ± 0.5 GHz; Return Loss: > 15 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 4: Stepped Impedance Hairpin Low-pass Filter (f-3dB: 2.4 ± 0.1 GHz; Pass-band Width: > 2.4 ± 0.1 GHz; 20 dB Stop-band: > 2.5 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
DESIGN AND IMPLEMENTATION OF BRF AND BPF FILTERS
CODE 170-008
Design and Implementation of BRF and BPF Filters
- Experiment 1: Open Stub Band-stop Filter (fc: 2.4 ± 0.1 GHz;-3 dB Stop-band Width: > 1 ± 0.5 GHz;-20 dB Stop-band Width: > 1 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 2: Compact Open Stub Band-stop Filter (fc: 2.4 ± 0.1 GHz;-3 dB Stop-band Width: > 1 ± 0.5 GHz;-20 dB Stop- band Width: > 1 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 3: Parallel Coupled Line Band-pass Filter (fc: 2.4 ± 0.1 GHz; Pass-band Width: > 0.5 ± GHz; -20 dB Stop-band Width: > 2 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 3 dB ± 1dB)
- Experiment 4: Wide Stop Band Band-pass Filter with Coupled Line and SIR Resonator (fc: 2.4 ± 0.1 GHz; Pass-band Width: > 1 ± 0.3 GHz;-20 dB Stop-band Width: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 3 dB ± 1dB)
PBG TYPE FILTER DESIGN
CODE 170-009
PBG Type Filter Design
- Experiment 1: Conventional PBG Low-pass Filter (f-3dB: 1.6 ± 0.1 GHz; -20 dB Stop-band Width: > 1 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 3 dB ± 1dB)
- Experiment 2: Chebyshev PBG Band-stop Filter (f-3dB: 2.4 ± 0.1 GHz; -3 dB Stop-band Width: > 1 ± 0.5 GHz; -20 dB Stop- band Width: > 1 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 2 dB ± 1 dB)
GDS TYPE FILTER DESIGN
CODE 170-010
DGS Type Filter Design
- Experiment 1: Low-pass Filter with Periodic DGS (f-3dB: 2.4 ± 0.1 GHz;-20 dB Stop-band Width: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 2: SIR Low-pass Filter with DGS (fc: 2.4 ± 0.1 GHz;-20 dB Stop-band Width: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 0 dB ± 1dB)
- Experiment 3: Parallel Coupled Line Band-pass Filter with Harmonic Stop (fc: 2.4 ± 0.1 GHz; Pass-band Width: > 0.3 ± 0.2 GHz; -20 dB Stop-band Width: > 3 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 3 dB ± 1 dB)
- Experiment 4: Open Stub Band-pass Filter using DGS Loaded (fc: 2.4 ± 0.1 GHz; Pass-band Width: > 0.4 ± 0.2 GHz; -20 dB Stop-band Width: > 1 ± 0.5 GHz; Return Loss: > 10 ± 5dB; Insertion Loss: < 3 dB ± 1 dB)
Manuals :
- All manuals are written in English
- Model Answer
- Teaching Manuals
General Terms :
- Accessories will be provided where applicable
- Manuals & Training will be provided where applicable
- Designs & Specifications are subject to change without notice
- We reserve the right discontinue the manufacturing of any product