Electrical Transformer Training Kit

g1-Electrical-protection-trainer-500x500-1.jpg

 

 

Electrical Transformer Training Kit

Model Number: GOTT-ETT-127

Brand: GOTT

C/O: Malaysia

 

DESCRIPTION

 

The behavior of current and voltage in a star connection with resistors at symmetric and asymmetric load, with and without neutral conductor connection, as well as in a delta connection can be coherently and thoroughly studied and taught. The operating characteristics of the most important transformers, single-phase transformers, single-phase isolating toroidal transformers, single-phase autotransformers, three-phase transformers at load condition, no-load condition and short circuit, can be safely studied and learnt by means of the experimental transformers.

 

Product Modules

  1. Adjustable Three Phase (Code 162-001):

            Protection Fuse 2A x 3 units

            Pilot Lamps L1, L2 & L3

            Fault Current Circuit Breaker 3 Poles

            Output: 0…240VAC x 3 units

                         0… 415VAC

            Input: AC 415V, 50Hz 3-Phase

 

  1. Inductive Load (Code 162-008):

            Protection Fuse 1A x 3 units

            Ranges: 0.2H, 0.4H, 0.6H,0.8H,1.0H x 3 units

 

  1. Resistive Load(Code 162-009):

            Protection Fuse 1A x 3 units

            Resistance: 0…1kΩ x 3 units

                               270Ω x 3 units

 

  1. Capacitive Load(Code 162-010):

            Protection Fuse 1A x 3 units

            Ranges: 1µF, 2 µF, 4 µF, 8 µF, 16 µF x 3 units

 

  1. Three Phase Transformer(Code 162-002):

            Protection Fuse 2A

            Output: 110VAC x 2 / Phase

            Input: 240VAC / Phase

 

  1. Auto Transformer(Code162-003):

            Protection Fuse 1A

            Output: 110VAC, 150VAC & 240VAC

            Input: 240VAC

 

  1. Cut Core Transformer(Code 162-004):

            Type: Cut Core

            Protection Fuse 1A

            Output: 110VAC x 2

            Input: 240VAC

 

 

 

 

 

  1. Toroidal Transformer(Code 162-005)

            Type: Toroidal

            Protection Fuse 1A

            Output: 110VAC x 2

            Input: 240VAC

 

  1. Shell Type Transformer(Code 162-006)

            Type: Shell Type

            Protection Fuse 1A

            Output: 110VAC x 2

            Input: 240VAC

 

  1. Varmeter(Code 162-007)

            Protection Fuse 1A

            Range: 0~VAR

 

  1. AC Voltmeter(Code 162-011)

            Measurement Mode: AC

            Voltage Ranges: 5V, 50V, 250V, 1000V

 

  1. AC Ammeter(Code 162-012)

            Measurement Mode: AC

            Voltage Ranges: 1A, 5A, 25A

 

  1. Fault Current Circuit Brreaker(Code 159-009)

            Protection Fuse 2A x 3 units

            Pilot Lamps L1, L2 & L3

            Fault Current Circuit Breaker 3 Poles

            Output: 0…240VAC x 3 units

                         0… 415VAC

            Input: AC 415V, 50Hz 3-Phase

 

  1. Intelligent Three Phase Electrical Meter(Code 162-013)

            Measurement: V, KV, Hz, A, KA, S, KW, KVAR, KVA, KWH, KVRH

 

  1. Safety U-Link(Code 446-000)

            A unit which is wed to link the unit together

 

  1. Standard Connecting Lead(Code 447-000)

            4mm standard connecting leads

 

 

 

 

  1. Vertical Frame (Code 297-000)

            High Level: Din Standard A4 with two Shelves

            Material: Aluminum

            Side Frame: T Shape

            Size: 3-Layer 1450mm Length

 

  1. Experiment Manual (Code 162-014)