Digital Storage Oscilloscope

Digital-Storage-Oscilloscope.jpg

Digital Storage Oscilloscope

Model: Number: GOTT-DSO-1000 Series

Brand: GOTT

C/O: Malaysia

FEATURES APPLICATION :

  • 500MSa/s & 1GSa/s Sampling Rate
  • 2 Channels
  • 7” Widescreen LCD Color Display (ADS1022C: 5.7 in)
  • USB Host/Device: Support USB Printer and USB Flash Drive
  • Pict Bridge Function
  • Easy scope Software
  • 12 Languages
  • Industrial Power Design, Troubleshooting, Installation, and Maintenance.
  • Electronics Design, Troubleshooting, Installation, and Maintenance
  • Circuit Design & Debug
  • Educational Lab & Training Institutions
  • Repair & Service
  • Production Test & Quality Inspection

PRODUCT SPECIFICATIONS :

  • Model-1102CML
  • Brand Width – 100MHz
  • Sampling Rate- 1Gsa/s
  • Equvalent- 50Gsa/s
  • Memory- Single Channel:2Mpts;Double Channel ;1Mpts
  • Rise Time- <3.5ns
  • Input Impedance- 1M Ohm//17Pf
  • Sec/div Range- 2.5ns/dia-50s/div
  • Display- 7″ LCD Color (480*234)

General Specification

  • Display Mode- Color TFT 7in diagonal Liquid Crystal Display
  • Resolution- 480 horizontal by 234 vertical pixels
  • Display Color- 64K color
  • Display Contrast- (Typical state) 150:1
  • Backlight Intensity- (Typical state) 300nit
  • Resolution- 480 horizontal by 234 vertical pixels
  • Wave display range 8 x 18 div
  • Wave Display Mode Point, Vector
  • Point Vector Off 1 sec, 2 sec, 5 sec, Infinite
  • Menu Display 2 sec, 5 sec, 10 sec, 20 sec, Infinite
  • Skin Succinct
  • Screen saver 1min, 2mins, 5mins, 10mins,15mins, 30mins, 1hour, 2hours,5hours,off
  • Waveform Interpolation Sin(x)/x, Linear
  • Color model Normal and Invert
  • Language English, French, German, Russian, Spanish, Simplified Chinese, Traditional Chinese, Portuguese, Japanese, Korean, Italian, Arabic
  • Interface USB Host, USB Device, RS232, Pass/Fail output

ENVIRONMENTS

  • Temperature
  • Operating 10°C to + 40°C
  • Not operating -20°C to +60°C
  • Humidity
  • Operating 85%RH, 40°C, 24 hours
  • Not operating 85%RH, 65°C, 24 hours
  • Height
  • Operating 3000m
  • Not operating 15,266m

POWER SUPPLY

  • Input Voltage 100-240 VAC, CAT II, Auto selection
  • Frequency Scope 45Hz to 440Hz
  • Power 50VA Max
  • Mechanical
  • Dimension
  • L x W x H- 399mm 110.5mm 148.5mm
  • Weight 2.4 kg

Vertical System

  • Vertical Sensitivity- 2mV-10div at input BNC(1-2-5order) 2mV-5V/div ( ADS1202CML/1022C)
  • Channel Voltage Offset Range- 2mV200mV:±1.6V, 206mV-10V in Fixed Gain Ranges & Variable Gain ranges
  • Vertical Resolution- 8bit
  • Analog bandwidth- (at input BNC)
  • Bandwidth- ADS1202CML – 200MHz , ADS1152CML – 150MHz ADS1102CML – 100MHz , ADS1062CML – 60MHz ADS1042CML – 40MHz , ADS1022CML – 25MHz
  • BW Flatness
  • DC-10% of rated BW ±1DB
  • 10%-50% of rated BW ±2DB
  • 50%-100% of rated BW ±3DB
  • Lower frequency limit (AC – 3dB)
  • 10Hz (at input BNC)
  • Noise Pk-Pk for 3K record 0.6Div for average of 10Pk-Pk readings in fixed gain settings. <=0.7 Div for average of 10 Pk-Pk readings, Variable gain settings
  • SFDR – including harmonics _40dB
  • DC Gain Accuracy : < ±3.0%: 5mV/div to 5V/div in Fixed Gain Ranges < ±4.0%:typical for 2mV/div&Variable Gain Ranges
  • DC Measurement Accuracy: All Gain settings _100mV/div ±[3%X (|reading|+|offset|) +1% of |offset| +0.2div+2mV]
  • Rise time, Typical (using 500ps pulse)
  • Bandwidth ADS1202CML – <1.8ns , ADS1152CML – <2.3ns ADS1102CML – <3.5ns , ADS1062CML – <5.8ns ADS1042CML – <8.8ns , ADS1022C ML – <14ns
  • Math operation +,-, *,FFT
  • FFT Window mode Hanning, Hamming, Blackman, Rectangular
  • Bandwidth limiter
  • Sampling points 1024
  • 20MHz ±40% Typical

HORIZONTAL SYSTEM

  • Real Time Sampling Rate Single Channel 1GSa/s; Double Channels 1GSa/s (ADS1202CML) Single Channel 1GSa/s; Double Channels 500MSa/s (ADS1000CCML Series) Single Channel 500MSa/S; Double Channels 250MSa/s (ADS1022C)
  • Equivalent Sampling Rate 50GSa/s
  • Measure Display Modes MAIN, WINDOW, WINDOW ZOOM, Scan, X-Y
  • Time base Accuracy ±100ppm measured over 10ms interval
  • Time Window 18 Divisions
  • Horizontal Scan Range – ADS1202CML ADS1152CML ADS1102CML ADS1062CML ADS1042CML ADS1022CML
  • 5ns/div – 50s/div , 5 ns/div – 50s/div 10 ns/div – 50s/div , 25ns/div – 50s/div
  • Scan: 100ms/div -50s/div (1-2.5-5 sequence)

INPUT

  • Input Coupling AC, DC, GND
  • Input Impedance
  • DC-1M_+/-2% || 17pF +/-3pF
  • AC-1.2M_+/-2% || 17pF +/-3pF, <=100mV/div
  • 0M_+/-2% || 17pF +/-3pF, >100mV/div
  • Maximum Input Voltage ±400V PK-PK CATI
  • Ch to Ch Isolation (Both)
  • Channels in same V/div setting) 100: 1 at 20MHz (ADS1042CML) 100: 1 at 100MHz (ADS1202CML), >100: 1 at 70MHz (ADS1152CML),100: 1 at 50MHz (ADS1102CML), > 100: 1 at 30MHz (ADS1062CML)
  • Probe attenuator 1X, 10X
  • Probe attenuator 1X, 10X, 100X, 1000X

 

HARD WARE FREQUENCY COUNTER

  • Reading resolution 6 Bytes
  • Accuracy ±0.01%
  • Range DC Couple 10Hz to MAX Bandwidth
  • Signal Types Satisfying all Trigger signal (Except Pulse width trigger and Video Trigger)

ACQUISITION SYSTEM

  • Sample Types Real time, Equivalent time
  • Memory Depth
  • ADS1202CML 5Kpts / CH
  • ADS1000CML Series Single Channel 2Mpts, ADS1022C Single Channel 4Kpts ; ADS1000CML Series

CONTROL PANEL FUNCTION

  • Auto Set Auto adjusting the Vertical, Horizontal system and Trigger Position
  • Save/Recall
  • Support 2 Group referenced Waveforms, 20 Group setups, 20 Group captured Waveforms internal Recall function and USB flash driver
  • Storage storage function.

TRIGGER SYSTEM

  • Trigger Types Edge, Pulse Width, Video, Slope, Alternative
  • Trigger Modes Auto, Normal, Single
  • Trigger Sources Ch1-2, EXT, EXT/5, AC Line
  • Trigger Coupling AC, DC, LF rej, HF rej
  • Trigger Level Range CH1, CH2 ±6divisions from center of screen
  • EXT: ±1.2V
  • EXT/5: ±6V
  • Trigger Level Accuracy (typical) applicable for the
  • signal of rising and falling time 20ns
  • Internal ±(0.2 div x V/div) ( within±4 divisions from center of screen)
  • EXT ±(6% of setting + 40 mV)
  • EXT/5 ±(6% of setting + 200 mV)
  • Edge Trigger Edge type Rising, Falling, Rising and Falling
  • Pulse Width Trigger
  • Trigger Modes (>, <,=) Positive Pulse Width, (>,<,=) Negative Pulse Width
  • Pulse Width Range 20ns-10s
  • Video Trigger Support signal Formats -PAL/SECAM, NTSC
  • Trigger condition odd field, even field, all lines, line Num
  • CH2 trigger type Edge, Pulse, Video, Slope

CHANNEL MODE SAMPLING RATE

  • Long and Short Memory
  • Single Channel 1Gsa/s 40kpts No Support 500MSa/s or lower 40kpts 2Mpts
  • Double Channels 500MSa/s or lower 20kpts 1Mpts
  • Sample Mode Sample, Peak Measure, Average
  • Averages 4,16,32,64,128,256

MEASURE SYSTEM

  • Auto Measure
  • Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms, ROVShoot, FOVShoot, RPREShoot,
  • FPREShoot, Rise time, Fall time, Freq, Period, +Wid, -Wid, +Dut, -Dut, Bwid, Phase, FRR, FRF, FFR,
  • FFF,LRR,LRF, LFR, LFF
  • Cursor Measure Manual mode, Track mode and Auto mode

TRIGGER SYSTEM

  • Slope Trigger (>,<,=) Positive slope, (>,<,=) Negative Slope
  • Time: 20ns-10s
  • Alternative Trigger CH1 trigger type: Edge, Pulse, Video, Slope

Manuals :

  • All manuals are written in English
  • Model Answer
  • Teaching Manuals

General Terms :

  • Accessories will be provided where applicable.
  • Manual & Training will be provided where applicable.
  • Design & specifications are subject to change without notice.
  • We reserve the right to discontinue the manufacturing of any product