Electrical Transformer Training Kit
Model Number: GOTT-ETT-127
Brand: GOTT
C/O: Malaysia
DESCRIPTION
The behavior of current and voltage in a star connection with resistors at symmetric and asymmetric load, with and without neutral conductor connection, as well as in a delta connection can be coherently and thoroughly studied and taught. The operating characteristics of the most important transformers, single-phase transformers, single-phase isolating toroidal transformers, single-phase autotransformers, three-phase transformers at load condition, no-load condition and short circuit, can be safely studied and learnt by means of the experimental transformers.
Product Modules
- Adjustable Three Phase (Code 162-001):
Protection Fuse 2A x 3 units
Pilot Lamps L1, L2 & L3
Fault Current Circuit Breaker 3 Poles
Output: 0…240VAC x 3 units
0… 415VAC
Input: AC 415V, 50Hz 3-Phase
- Inductive Load (Code 162-008):
Protection Fuse 1A x 3 units
Ranges: 0.2H, 0.4H, 0.6H,0.8H,1.0H x 3 units
- Resistive Load(Code 162-009):
Protection Fuse 1A x 3 units
Resistance: 0…1kΩ x 3 units
270Ω x 3 units
- Capacitive Load(Code 162-010):
Protection Fuse 1A x 3 units
Ranges: 1µF, 2 µF, 4 µF, 8 µF, 16 µF x 3 units
- Three Phase Transformer(Code 162-002):
Protection Fuse 2A
Output: 110VAC x 2 / Phase
Input: 240VAC / Phase
- Auto Transformer(Code162-003):
Protection Fuse 1A
Output: 110VAC, 150VAC & 240VAC
Input: 240VAC
- Cut Core Transformer(Code 162-004):
Type: Cut Core
Protection Fuse 1A
Output: 110VAC x 2
Input: 240VAC
- Toroidal Transformer(Code 162-005)
Type: Toroidal
Protection Fuse 1A
Output: 110VAC x 2
Input: 240VAC
- Shell Type Transformer(Code 162-006)
Type: Shell Type
Protection Fuse 1A
Output: 110VAC x 2
Input: 240VAC
- Varmeter(Code 162-007)
Protection Fuse 1A
Range: 0~VAR
- AC Voltmeter(Code 162-011)
Measurement Mode: AC
Voltage Ranges: 5V, 50V, 250V, 1000V
- AC Ammeter(Code 162-012)
Measurement Mode: AC
Voltage Ranges: 1A, 5A, 25A
- Fault Current Circuit Brreaker(Code 159-009)
Protection Fuse 2A x 3 units
Pilot Lamps L1, L2 & L3
Fault Current Circuit Breaker 3 Poles
Output: 0…240VAC x 3 units
0… 415VAC
Input: AC 415V, 50Hz 3-Phase
- Intelligent Three Phase Electrical Meter(Code 162-013)
Measurement: V, KV, Hz, A, KA, S, KW, KVAR, KVA, KWH, KVRH
- Safety U-Link(Code 446-000)
A unit which is wed to link the unit together
- Standard Connecting Lead(Code 447-000)
4mm standard connecting leads
- Vertical Frame (Code 297-000)
High Level: Din Standard A4 with two Shelves
Material: Aluminum
Side Frame: T Shape
Size: 3-Layer 1450mm Length
- Experiment Manual (Code 162-014)